            Data Center Map

            AdNet - DataCity Bucharest


            » Index » Romania » Bucharest » AdNet - DataCity Bucharest

            AdNet - DataCity Bucharest is located in the area Bucharest, Romania, and the colocation data center is carrier neutral. The data center was last updated on 04-07-2017.


            Address:
            AdNet Telecom
            Blv. Pipera, Nr.1/VI
            077190 Voluntari
            Ilfov, Romania

            » Request quote
            » Visit website

            Click here to find other data centers
            owned and operated by AdNet Telecom.


            Profile
            Gallery
            Tenants
            Connectivity
            Request quote
            Office space
            Rack Cabinets
            Dedicated Servers
            Suites
            Footprints
            Virtual Servers
            Cages
            Hosting of individual servers
            Remote Hands

            Profile


            TIER III DESIGN:
            Availability higher than 99.982%
            Redundant power elements with independent
            circuits paths configured in as 1+1
            Redundant cooling elements with
            independent circuits paths configured in as N+1
            Provides concurrent maintenance

            ENERGY EFFICIENT:
            Optimized IT Equipment arrangement in Cold/Hot Aisle
            Advanced multistep cooling control allow for high efficiency
            Integration of green energy such as photovoltaic and wind turbine
            High performance rectifiers, inverters and accumulators in UPS system
            Targeted PUE - Power usage effectiveness lower than 1.3 for 100% load
            Actual PUE - 1.75 at 20% Load

            IT & TELECOM INFRASTRUCTURE:
            IT infrastructure design for TIER III
            Multipath optical fiber on 3 circuits
            High end border routing equipment Juniper MX series
            Data Center L2 and L3 switching performed by Cisco Nexus
            Complex evolved virtualization platform based on Cisco UCS, HP 3PAR
            storage and VMWare VCenter/Vsphere
            Cluster balancing technology from A10 Networks
            Advanced traffic anomaly detection and cleaning with Arbor System technology
            Complete internal data circuits distribution with Panduit materials

            COOLING:
            Adiabatic & Free cooling - Indoor for IT Containers:
            60 racks with average power of 7 KW arranged in 3 cold aisle with 20 racks each resulting in a total power of 140KW / cold aisle
            24 LCU providing 20KW of cooling arranged in 3 cold aisle resulting in 8 units / row with a capacity of cooling of 160KW (7+1)
            In-line positioning with racks, Cold-Isle/Hot Isle containment with front to back airflow
            Cooling agent: thermic agent with heat transfer properties optimized for whole range of meteorological conditions
            Chiller water cooling - Outdoor:
            3 x 300KW chiller units with Free Cooling mechanism
            "Air-Conditioning" type water cooling - compressors based in 12 steps (4 independent compressors / chiller unit)
            N+1 Redundant compressors, ventilators and other components (according to TIER III standards for cooling)
            Automation system for adjusting electrical energy consumption
            Adiabatic & Free cooling - Indoor for Power containers
            4 units 30KW
            N+1 redundancy type according to TIER III standards for power supply

            POWER & UPS:
            Total installed power 480 kW x 2 with redundancy in 2 lines
            2 automatic back-up diesel generators one for each line
            Accumulators pack - 108 with 100 Ah capacity for each power box
            2 UPS of 40 kVA for chiller pumps
            2 UPS of 20 kVA for interior modules of inline cooling units
            2 heating pumps and 1 ice pillar for extra heat removal before Chillers
            1 wind turbine with 2 KW - providing auxiliary power
            80 x 250W (20 KW) photovoltaic farm - compensating in extra hot summer days

            RACKING & VIRTUALIZATION:
            Racks
            Hardened steel Racks:
            45U racks space proving at least 42U usable IT Equipment
            Depth: 1000mm
            Width: standard 19''
            PDU: for each Rack 2 PDU three-phase power supply of 400V - Maximum power 11 KW redundant/ Rack, each PDU with 24 IEC13 sockets and 6 IEC19 sockets
            Assembling on metallic anti vibration and anti seismic system

            Virtualization system
            Cisco UCS Blade Server System
            5 x Blade server chassis each with 8 blade server units installed
            Installed processing power ~ 1800 VCPU
            Installed memory : 7168 GB
            HP 3PAR 7400 Enterprise Storage Dual controller with 200TB of usable space (250TB installed)
            Storage: even mix of SAS/NL-SAS disk
            Switching: Integrated Cisco switch fabric with extra 32 port 10GB for external connectivity
            VMWare VSphere/VCenter Enterprise plus virtualization system

            SECURITY SYSTEM:
            Complex security system
            Fire detection system
            Smoke detection sensor
            Temperature sensor
            Fire extinguisher cylinders
            Fire detection station
            Exterior fire alarm control panel from fast access from outside
            Dual power source, both from main power supply and UPS
            Access control module
            Emergency fire path - both mechanical and electromagnetic
            Magnetic stripe card access
            Unlimited user access with multiple roles and rights
            Control panel integration with fire detection and extinguisher system - automatic fire path unlocking
            Real time reports and history : access type, users, access path, etc.
            Surveillance system
            HD IP cameras
            NVR recording and monitoring
            Minimum 30 days data storage in

            INFRASTRUCTURE MANAGEMENT:
            Complex monitoring and management software suite integrating all hardware and software components installed in the datacenter infrastructure (power elements, cooling elements, security & surveillance, sensors & monitoring devices)
            Data center components detailed charts and schematics (racks, cooling, power, surveillance, control access, sensors, etc.)
            IT Equipment layout
            Power supply, circuits and distribution
            Chillers, LCU, cooling paths
            Surveillance, access control, firefighting systems
            Humidity, temperature, air quality, flood sensor system
            Renewable energy controllers
            Real time & Historical monitoring for all managed systems
            Statistics, Graphics and Analysis of various parameters
            Friendly graphical web user interface compatible with most modern browsers

            CONNECTIVITY:
            Physical connections (L1):
            3 paths geographically and logically independent underground optical fiber links - 144 optical wires available
            Open Third-party fiber optic interconnection cabinet easily accessible from any underground infrastructure
            Logical connections (L2-L3):
            Data center node is included in main N x 10Gbps metropolitan multi-ring core network of 2K Telecom, providing high capacity resilient communications with most POP or exchange nodes
            Juniper MPLS Switches and Routers provide any type of logical connection (L2 circuits, VPLS, L3 VPN, QinQ, Dark Fiber, TDM transport, etc.)
            External connections (National&Internet)
            2KTelecom is member of public Internet Exchanges: Interlan, Balkan-IX RoNIX, NxData, IBM Data Center, INES Datacenter, Cyberhost Datacenter
            Extra private national interconnection with leading ISP providers improve capacity and latency
            Optimized Balanced Access to Internet is achieved through major world wide Internet Carriers (M247/NTT, Telekom/LEVEL3)








            AdNet - DataCity Bucharest Pricing/Quotes


            If you are interested in receiving a quote for AdNet Telecom, please try our free quote service.