日本一本道不卡视频在线大全

      1. <code id="jjto2"><nobr id="jjto2"><sub id="jjto2"></sub></nobr></code>
        <big id="jjto2"><em id="jjto2"></em></big>

            <strike id="jjto2"></strike>

            <tr id="jjto2"></tr>
            Data Center Map

            Mobily Tier-2 Unaizah


            » Index » Saudi Arabia » Unaizah » Mobily Tier-2 Unaizah

            Mobily Tier-2 Unaizah is located in the area Unaizah, Saudi Arabia (Kingdom of Saudi Arabia (KSA)), and the colocation data center is carrier neutral. The data center was last updated on 21-01-2014.


            Address:
            Mobily
            qassim
            114423 Unaizah
            Unaizah, Saudi Arabia

            » Request quote
            » Visit website

            Click here to find other data centers
            owned and operated by Mobily.


            Profile
            Tenants
            Connectivity
            Request quote
            Office space
            Rack Cabinets
            Dedicated Servers
            Suites
            Footprints
            Virtual Servers
            Cages
            Hosting of individual servers
            Remote Hands

            Profile


            MECHANICAL SYSTEMS:
            -----------------------------

            a-Cooling System : Chilled water cooling system Variable primary flow system with single supply and return.

            b-CRAH redundancy: N+1 demand cooling for equipment is 600 w/m.

            c-Fuel Oil: Generator fuel oil storage 72 hours capacity.

            d-BMS: Computerized Building Management System M&E equipment verification and management.

            ELECTRICAL SYSTEMS
            --------------------------
            a-Design load: The electrical connected load is 4.00MVA with a demand load of 2.8.

            b-Transformers: 2 x 1500 KVA and 2 x 1000 KVA .

            c-Generators : 3 x 1600 KVA/1280 KW, 380/220v prime rated diesel generators, design N+1.

            d-Paralleling Switch gear: One set of paralleling switch gear for concurrently maintainable requirements.

            e-UPS: Parallel redundant system in N+N configuration, 200KVA modular units with 30 minute battery autonomy at full load.

            f-Rectifier System: Active + Active System, (N+N) at 200 W/m2, 1000 Ah for 2 hrs + 2hrs battery autonomy time.

            g-Security System :Security Analog access control system and IP CCTV integrated with BMS


            Mobily Tier-2 Unaizah Pricing/Quotes


            If you are interested in receiving a quote for Mobily, please try our free quote service.

            Copyright © Data Center Map - Sitemap
            Your guide to colocation data centers, managed hosting, cloud servers etc.
            日本一本道不卡视频在线大全
              1. <code id="jjto2"><nobr id="jjto2"><sub id="jjto2"></sub></nobr></code>
                <big id="jjto2"><em id="jjto2"></em></big>

                    <strike id="jjto2"></strike>

                    <tr id="jjto2"></tr>