            Data Center Map

            VeratNet


            » Index » Serbia » Belgrade » VeratNet

            VeratNet is located in the area Belgrade, Serbia (Republic of Serbia), and the colocation data center is not carrier neutral. The data center was last updated on 24-08-2010.


            Address:
            Verat
            37 Vovjode Misica Blvd
            11000 Belgrade
            Serbia

            » Request quote
            » Visit website

            Click here to find other data centers
            owned and operated by Verat.


            Profile
            Tenants
            Request quote
            Office space
            Rack Cabinets
            Dedicated Servers
            Suites
            Footprints
            Virtual Servers
            Cages
            Hosting of individual servers
            Remote Hands

            Profile


            Basic facts

            VeratNet's Data Center is one of the most modern facilities of this kind in the country. It is projected according to modern trends of ANSI-TIA standards for facilities of this kind, and is situated within the VeratNet's commercial building in 37 Vojvode Misica Boulevard.
            . Guaranteed redundancy of all systems (UPS equipment, air conditioning, network wiring)
            . High quality components
            . Reliability and availability of 99.999%
            . 55 cm high floor
            . Local redundant cabling and floor cooling located below the floor
            . Optimal temperature for equipment functioning
            . Internal cabling with redundant fiber optic cables
            . Users connected to all international Internet links available in the country
            . Equipment located in 42U racks
            . Highly sophisticated system of surveillance
            . 24 / 7 video surveillance system with restrictive access control
            . Modern fire detection system
            . Senior level administrators are always available for the highest possible level of support

            Electricity supply

            . The system secured with 2 +1 redundancy (MGE Galaxy 5000 100kVA UPS)
            . 400 kVA Caterpillar diesel - started automatically in case of power cuts
            . Uninterruptible power supply and a minimum possibility of power failure


            Access Control and Video Surveillance

            We provide you with the highest level of security to your equipment, 24 hours a day. With multiple levels of security, entering the data center is controlled by proximity cards and access codes.
            . No public access to the data center is available
            . Alarm system for intrusion detection
            . Full motion video camera
            . Constant supervision of entrance and data center
            . The card and access code required to enter the data center
            . Database of individuals with access control
            . Man Trap Security - only authorized personnel can enter the data center
            . 24/7/365 monitoring
            . 6 APC NetBotz surveillance cameras
            . Locked racks for every server
            . Registration of equipment serial numbers
            . Emergency access for all customers with priority
            . Electronic record of every access
            . Overseeing the environment to prevent damage to equipment

            Fire-extinguishing System

            VeratNet's data center is protected by fire systems in two zones. System FM200 fire extinguishers without the use of water allow the best possible fire protection.
            . The system for fire detection in two areas
            . Photoelectric smoke detectors for early warning
            . Warning heat systems as a secondary system of protection
            . FM 200 fire alarm system - based on a harmless gas
            . Fire extinguishing systems with double dry tube
            . Water - outside the critical equipment area
            . The sprinklers do not damage the equipment
            . Alarm system without the possibility of error - prevents false activation or a mistake
            . Activation of the pre-action, specific to a particular zone
            . Smoke tube in accordance with regulations




            VeratNet Pricing/Quotes


            If you are interested in receiving a quote for Verat, please try our free quote service.

            Copyright © Data Center Map - Sitemap
            Your guide to colocation data centers, managed hosting, cloud servers etc.