            Data Center Map

            Cogent Chicago 1


            » Index » USA » Illinois » Chicago » Cogent Chicago 1

            Cogent Chicago 1 is located in the area Chicago, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 26-12-2018.
            This data center is located within 427 LaSalle.

            Address:
            Cogent Communications, Inc.
            427 LaSalle St
            60606 Chicago
            Illinois, USA

            » Request quote
            » Visit website

            Click here to find other data centers
            owned and operated by Cogent Communications, Inc..


            Profile
            Tenants
            Connectivity
            Request quote
            Office space
            Rack Cabinets
            Dedicated Servers
            Suites
            Footprints
            Virtual Servers
            Cages
            Hosting of individual servers
            Remote Hands

            Profile


            On-Net Products
            . IP Transit
            . Ethernet Transport Services

            Standard Rack Configuration
            . 42U APC Cabinets (Model: AR3100)
            . Power extra (110v/20 amp or 2 X 110v/20 amp is standard)

            Carrier Availability
            . Verizon
            . XO

            Facilities
            . 2,300 square feet of raised floor data center space
            . 480v 3-phase utility feed - 400 amps

            Security
            . C*CURE Software House Card Reader Access Control System
            . 24/7 manned building security
            . (2) IP cameras in use with recording and 24/7/365 monitoring capabilities to the Cogent NOC (1) at main entrance into facility

            Generator Systems
            . 250kW Onan/Cummins Diesel Generator
            . 500 gallon diesel storage tank
            . Automatic Transfer Switch

            UPS Systems
            . 1 UPS Module @ 80 KVA
            . Model: Powerware Plus 80 Model 80

            Batteries
            . 1 string of 40 batteries for UPS Unit

            HVAC
            . 3 DataAir 13-ton HVAC units with rooftop mounted condensers units.

            Electrical/Fire/Monitoring
            . 1 Powerware PDU (Model PDM-21-450)
            . Fire Detection and Suppression consists of above and below floor smoke heads and FM200 tanks


            Cogent Chicago 1 Pricing/Quotes


            If you are interested in receiving a quote for Cogent Communications, Inc., please try our free quote service.

            Copyright © Data Center Map - Sitemap
            Your guide to colocation data centers, managed hosting, cloud servers etc.
            日本一本道不卡视频在线大全
              1. <code id="jjto2"><nobr id="jjto2"><sub id="jjto2"></sub></nobr></code>
                <big id="jjto2"><em id="jjto2"></em></big>

                    <strike id="jjto2"></strike>

                    <tr id="jjto2"></tr>